110 VOLT TRANSFER
SWITCH INSTALATION
November 6, 2017
Page
1
of
8
BC Ambulance Service, Fleet Operations
1 877 652-7465
Block C, 2261 Keating X Road
Fax: 250 952-0275
AMBULANCE TYPE:
CRESTLINE SINGLE STRETCHER
UNITS AFFECTED:
ALL CRESTLINE SINGLE STRETCHER UNITS EQUIPPED
WITH THE STRYKER POWERPRO STRETCHER
ISSUE:
To provide 110V power to the internal receptacles of the ambulance from
shoreline power or the Go Power inverter, to facilitate charging of the
Stryker PowerPro Stretcher battery.
ACTION:
INSTALLATION OF AN 110V TRANSFER SWITCH
LABOUR TIME:
1.5 hrs
LABOUR CODE:
GMOTS
SERVICE PROCEDURE:
Please read through this modification entirely before starting modification.
Contact BCAS Fleet Operations if there are any questions or concerns.
1-877-652-7465
Check contents of kit provided.
2 Marrets - 110V connectors
1 female 110V plug
6 Self tapping screws #10 x 5/8
2 Cover Screws #10-32 x 5/8
2 cable clamps
3 Zap straps
Mounting Bracket – Crestline
Transfer Switch
Plastic hole plug
BEFORE STARTING THIS MODIFICATION:
Confirm 110 volt power is not connected to the ambulance shoreline power and the engine is
switched off.