110 VOLT TRANSFER
SWITCH INSTALATION
November 6, 2017
Page
7
of
7
BC Ambulance Service, Fleet Operations
1 877 652-7465
Block C, 2261 Keating X Road
Fax: 250 952-0275
System Test:
Using a GFI protected circuit; plug a shoreline power cord into the lower 110V shore power receptacle on the
outside of the ambulance.
Plug an 110V tester into each of the patient compartment 110 volt outlets – power should be present.
Note:
There is a second outlet located in the kit tree.
Start the engine and turn the connect switch on. Unplug the shore power from the outside of the ambulance.
Confirm the 110V outlets in the patient compartment still have power.
Labour Code: GMOTS – use this labour code on the invoice and charge 1.5 hrs.
Step 7
In the patient compartment, remove the lower
box labeled “Inverter Power”.
Pull the power cord wire out with the box.
Step 6
Re-install the Breaker Box Cover.
Use a razor blade to trim and peel the
remaining box decal to read:
Power 110 Volt AC