1 / 3 Next Page
Information
Show Menu
1 / 3 Next Page
Page Background

ALTERNATOR FEED FUSE

INFORMATION BULLETIN

IB-008 REV 1

2013-03-20

Page 1 of 1

1

AMBULANCE TYPE:

628XX AND 629XX series

ISSUE

This bulletin is to inform Service Managers that service BC Ambulance fleet of

Demers Ambulances that some units may experience charging issues on the OEM (GM)

cluster. In some instances the alternator feed wire had received a voltage spike while

starting the unit causing the existing fuse or manual reset breaker to trip. As a result the

alternator does not sense correct voltage causing an error message in the OEM cluster.

ACTION

It was requested by BC Ambulance based on Demers recommendations of previous

experience to have all alternator feed fuses or manual reset breakers be replaced with an

auto-reset breaker. It is recommended; at the time of failure to replace either the fuse or the

manual reset breaker with an auto-reset breaker as detailed in this bulletin.

If you have any questions, contact our Demers Customer Assistance Centre service

department at following phone number 1-800-363-7591ext.282

and ask for Dominic

Chatelle.