Rico Suction Unit RS-4X Upgrade

January 16, 2017

Page

3

of

6

AMBULANCE TYPE:

Crestline

UNITS AFFECTED:

63003 – 63005 and Remounted 63000 series

For any questions or concerns, contact BC Ambulance Service, Fleet Operations

1 877 652-7465

Block C, 2261 Keating X Road

Fax: 250 952-0275

On the interior wall, center the vacuum face plate

over the hole where the vacuum hose came

through the wall. Mark the retaining screw holes.

Be sure the face plate is square on the panel.

Use a hole saw to cut a 1

1/8

” hole for

vacuum hose. Drill appropriate size

pilot holes for the retaining screws.