# ASS :
Y. DUBÉ
INTERSECTION LIGHT « STEADY-BURN »
DEACTIVATION FEATURE
(UNIT 62911 TO 62979)
J3
ECU1
This modification is for unit number
62911
to 62979
1 - Locate connector
J3
on
module ECU-1
.
2 -
Remove
connector
J3
and
locate pin 7 - left flasher / pin 8 - right flasher
(see diagrams on page 2)
3 -
Cut
and
insulate
wires at both ends on
pins 7 & 8
(yellow & green wires).
4 - Reinstall connector
J3
and
make sure left and right flashers work
on side and rear of the ambulance module.