INTERSECTION LIGHT « STEADY-BURN »

DEACTIVATION FEATURE

(UNIT 62911 TO 62979)

J3

ECU1

This modification is for unit number

62911

to 62979

1 - Locate connector

J3

on

module ECU-1

.

2 -

Remove

connector

J3

and

locate pin 7 - left flasher / pin 8 - right flasher

(see diagrams on page 2)

3 -

Cut

and

insulate

wires at both ends on

pins 7 & 8

(yellow & green wires).

4 - Reinstall connector

J3

and

make sure left and right flashers work

on side and rear of the ambulance module.