Power Inverter Diode

Installation

November 21, 2016

Page

1

of

3

AMBULANCE TYPE:

Demers Chevrolet Ambulances

UNITS AFFECTED:

63300-63349, 63360-63369, 63400-63457

Contact Fleet Operations for any questions or concerns

BC Ambulance Service, Fleet Operations

1 877 652-7465

Block C, 2261 Keating X Road

Fax: 250 952-0275

ISSUE:

GM Recall “42230 Shortened Powered Accessory Availability” reprograms the

vehicle’s PCM and BCM for the alternator to produce more voltage. This higher voltage

causes the ambulance power inverter to produce an “Over Voltage” trouble code,

causing the power inverter to stop working.

ACTION:

Install the supplied diode in the Power Inverter switch/sensor circuit at the

next A service or at the earliest opportunity.

LABOUR TIME:

Bill to BC Ambulance .2 HRS

LABOUR CODE: CMOID

Use the above labour code

on the invoice to identify this procedure has been

completed.

SERVICE PROCDURE:

Follow the picture instructions below. Be sure to read the complete instructions before

performing the modification.

Identify if the inverter you are working on is an option A or B.

Follow the corresponding instructions below for the affected option.