11159 - BCEHS Acetech R01b
-W8 -W8 -W8 -EB1 33091 A B C D E F G H I 1 2 3 4 5 6 7 8 9 10 Sheet Drawn By Designer Checked By Last Rev. System Subsystem Revisions: REV ALL INFORMATION ON THIS DRAWING IS CONFIDENTIAL. ALL COPIES OF THIS DOCUMENT MUST BE RETURNED OR DESTROYED UPON REQUEST BY CRESTLINE COACH. of Vehicle BU-11159 13 63 TJP MCK 12/14/17 MCK 120V Distribution 01 Move Outlet Breaker to Output side of Transfer switch, add extra junction block Initial Release Inverter / Charger /18.D2 /56.F6 /53.G7 /56.F6 /18.C9 /14.I2 /14.I2 /14.I2 /12.E8 /12.E8 /12.E8 PROwatt SWAutoTransfer Switch AC INPUT1 INVERTER AC INPUT2 UTILITY AC OUTPUT A/C INPUT DC OUTPUT /53.C1 /53.G7 /56.G6 /56.G6 N L1 /13.G6 /13.H6 /13.H6 /13.D1 /13.D1 /13.D1 /53.I2 N L1 DC INPUT A/C OUTPUT GFCI S1 1 2 3 4 1 0 FREQ VOLT PWR Switch ON OFF REM PWR SAVE SHORELINE +ECC BOARD-C464M:10 GND +ECC WALL-JB2 GND +ECC WALL-JB2 L2.Inverter_Line1 +STREETSIDE MCC-RCP1:L1_LINE N2.Inverter_Neutral1 +STREETSIDE MCC-RCP1:N_LINE GND.Inverter_GND1 +STREETSIDE MCC-RCP1:GND ENGINERUNPWR +ECC BOARD-C464M:9 L1.Inverter_Line_In +CONVERSION STREETSIDE-RCP13:L1 N1.Inverter_Neutral_In +CONVERSION STREETSIDE-RCP13:N GND.Inverter_GND_IN +CONVERSION STREETSIDE-RCP13:GND BATTLIVE01 -FH5:4 36755 -SW22 -R20 2 4 32789 CHASSISBATT01 -BUTT198:1 BATTLIVE01 -BUTT199:1 +ECC WALL-JB2 +ECC WALL-JB2 L1/3 -C413 N/3 GND/3 -C414 *3/3 10346 -C413 *3/3 10347 -C414 1 2 -B41 15 43410 1 2 -B42 10 43409 43420 -X1 -R20 0 1 32789 -X1:PE N1 -R20:0 GND -RT3:1 L1 -R20:1 N1 -X1:N L1 -X1:L1 GND -X1:PE AMBCONNECTPWR +ECC BOARD-C464F:14 21218 21218 -A2 DIN RAIL 41387;0.076 41674;2 43420 -X3 3151 -CHRG1 TrueCharge 2 40ACharger L N BATT1+ BATT2+ CASE_GND G BATT3+ COMMON- 43257 -INV1 CASE GND RJ11 Remote 1 - NO Cont. 2 - COMM 3 - NC Cont. 4 - Enable + 5 - Enable - 6 - Ground Neut. GND POS(+) NEG(-) Line Line Neut. GND Ensure S1 DIP switches are set as Shown Leave Power switch in REMOTE position Plug Transfer Switch Directly into Inverter Ground Electrical Box Press and hold the button for three seconds to change charger Setting Charger Mode - 3 Stage (Default) Battery T pe - AGM Battery Temp - Warm 20cm (8in) Service Loop Requred on Harness Install 4341 into 120V breaker screw holes after tightening Six (6) inches of DIN rail used to mount all (3) 120Vac Breakers. BLK6 BLK4 106/4 L1 N GND 10601 -W5 -W5 -W5 21 BLK6 BLK6 N GND L1 -W8 -W8 -W8 10601 -W4 -W4 -W4 10601 L1 L1 N GND N GND -W10 10601 -W10 -W10 10601 46/6 106/6 140 36 L1 N GND BK GN WT N L1 GND
Made with FlippingBook
RkJQdWJsaXNoZXIy ODc2NzI=